4.1 PROGRAM MENU
To enter the program MENU press the SEL() button once.
The LCD display will change to show: “ENTER PASSWORD” with
the 1
st
digit code number shown as “0”
To be able to enter the programming MENU the correct four-digit user code must now be entered
as follows:
1. Select the 1st digit of the user code by using the UP&DOWN buttons – Then press SEL();
2. Select the 2nd digit of the user code by using the UP&DOWN buttons – Then press SEL();
3. Select the 3rd digit of the user code by using the UP&DOWN buttons – Then press SEL();
4. Select the 4th digit of the user code by using the UP&DOWN buttons – Then press SEL();
If the correct code has been entered the display will change to show:
“SECURITY LEVEL” followed by the current security level set e.g.
“LEVEL 03”
If the incorrect code has been entered the display will momentarily change to show: “PASSWORD
ERROR” and return to the normal operating display.
NOTE: Contact your dealer or the company with the serial number of your
ThruScan
or
your invoice information if you forget your password.
4.1.1 SECURITY LEVEL & SENSITIVITY LEVEL ADJUSTMENTS
ThruScan s3-s6-s9 :
Consisting of 10 separate security levels (channels), each security level (except for NC levels) can
be set to operate at a different sensitivity level. It is possible to adjust a total of 246 sensitivity
levels from security level 000 (the highest sensitivity) to 245 (the lowest sensitivity).
ThruScan sX/sX-WP/s15-i/
sX-i :
Consisting of 20 separate security levels (channels), each security level (except for NC level) can be
set to operate at a different sensitivity level. 5 Fixed International Sensitivity Standard (optional). It
is possible to adjust a total of 246 sensitivity levels from security level 000 (the highest sensitivity)
to 245 (the lowest sensitivity). In this very distinctive feature ; The security Level is defined and
assigned by the AD-Auto Designation technique and consequently the relative, pre-selected
“Security Level/Channel” is set. See Section 4.1.3 for further details.
Factory default settings Security Levels for ThruScan s3/s6/s9 and ThruScan sX/ sX-
WP /s15-i/sX-i are as follows;
ENTER PASSWORD
[0 ]
SECURITY LEVEL
[03]